MPPT 30A Solar Charge Controller 12V 24V auto switch MPPT-30 adopts DC/DC converting technology and MCU technology.
It can adjust the working point of the solar panel array intelligently to make the solar panel array realize the maximum power output.
When the external condition changes, the empty controller bases on the MCU theory tracks the maximum working point of the solar panels, this can improve the using efficiency of the solar panels and decrease the solar generating cost. Compared with average solar charge controllers, eMPPT can improve the output efficiency of the solar panels by 5% to 30 %( the output increasing proportion is affected by the factors such as the attribute of the solar panels, environmental temperature and lighting conditions).
The product adopts in big-screen lattice LCD and uses vivid icons to indicate the parameters. It has a concise and vivid interface.
The product is wall mounting installation. Please refer to chapter 2.1 for the installing dimensions.
Functions:
1. Max. power point tracking: Adopting DC/DC converting technology and MCU technology to realize the maximum output of the solar panels;
2. Battery reversed connection protection: Battery polarity connecting to the controller reversely (under the condition of not connecting solar panels) will not cause damage to the controller. It can work normally after connecting right;
3. Anti-battery reverse discharge: When solar panels voltage is less than battery voltage, the battery will not charge to the solar panel's array;
4. Anti-solar panels reverse connection: Solar panels array polarity connecting to the controller reversely will not cause damage to the controller. It can work normally after connecting right;
5. Three-stage charge control: Bulk Absorption Float;
6. Float charging voltage adjustable: The users can adjust the float charging voltage within a certain scope.
7. Temperature compensation for float charging voltage: Referring to the current battery temperature, take 25°c as a benchmark, the controller will compensate the float charging voltage by -4mV/Cell/°c. For 12V battery, compensation voltage U=(t-25)*6*(-0.004)V;For 24V battery, compensation voltage U=(t-25)*12*(-0.004)V;For 48V battery, compensation voltage U=(t-25)*24*(-0.004)V
8. Elevating charging voltage adjustable: The users can adjust the elevating charging voltage within a certain scope
9. Solar panel input deviated from maximum power point: When solar panel input power is over the acceptable power for the controller, the controller will make the solar panel work deviated from the maximum power to prevent itself damaged. So the controller charges the battery by the rated current.
10. Internal overheating protection: When the internal temperature sensor detects excessive temperature, the controller will stop working to prevent it from being damaged. It will resume working again when the internal temperature drops to a certain degree.
11. Temperature controlling fan: When the internal temperature sensor detects the temperature exceeding a certain degree, the controller will start the cooling fan until the temperature drops to a certain degree.
12. Panel over-voltage protection: When the input voltage of the solar panels exceeds the rated voltage, the controller will start protection automatically and stop working until the input voltage resumes back to the normal scope.
13. Remote controlling function: This optional function can make it possible to view and set the parameters of the system on a PC.
Technical parameters:
Model | | |
Input | Solar panel input voltage scope | ≤70V | |
Maximum power point voltage tracking scope | 12V~70V(12V) | |
24V~70V(24V) |
solar panel input route | 1 route | |
rated working voltage | 12V/24V auto switch | |
maximum charging current | 30A | |
no-load loss | ≤45mA | |
charging mode | (Bulk Absorption Float) |
Output | float charging voltage | 27.6V(adjustable) | |
temperature compensation for float charging voltage | -4mV/cell/°c | |
absorption charging voltage | 28.8V(adjustable) | |
temperature scope | -20°c~+70°c | |
protection functions | battery reverse connection function |
battery reverse discharging function |
solar panel reverse connection function |
solar panel input over-voltage protection |
radiator overheat protection |
input over power deviated from the maximum power point |
cooling way | thermostat active cooling |
Others | optional function | (RS485 or RS232) remote controlling function |
working temperature scope | -10°c~+50°c |
working altitude | ≤3000m |
working humidity scope | 0~90%, no condensation |
volume | 380*150*100mm |
weight | 2.5 Kg | 2.6 Kg |
storage temperature scope | -30°c~+80°c |
Talkers Energy undertakes a strict quality control system and insists on perfect workmanship and the use of top quality materials.
And our products have been CE, CB and SASO certified. Our pursuit of first-rate quality, competitive prices and considerate after-sales services offers both potential and long-standing client confidence in our company