Combustible Gas Detector Naturaas Alarm r Practical Home Security Lpg Leakage Detector 110-240V
Features : 1. High quty gas r, no paivation, it has lower power consumption and longer service life. 2. Unique design, it can sense gas, naturaas, liquefied petroleum gas. 3. Single intelligent control, self-detection can prevent false alarm and eliminate false alarm, stable and reliable. 4. Can be used alone, or connected with solenoid valve/manipulator control system, features function of sound light alarm and automatic reset. 5. Easy to install, save time and effort. No alarm within 2-3 minutes ar power on. Specification : Condition: 100% Working Voltage: 110-240v Static Power Consumption: < 2w Alarm Concentration: Liquefied Gas 0.1% - 0.5%; Naturaas 0.1% to 1%; City Gas (H2) 0.1-0.5%; Carbon Monoxide 0.1 to 0.4 Percent Gas Response Recovery Time: ≤30s; Carbon Monoxide Response Recovery Time: ≤200s Alarm Volume: ≥70dB Working Envment: Humidity ≤97%rh; Temperature 15 ℃ - + 50 ℃
Transmiion Frequency: 315MHZ
En : PT2262
Optional Plug: US, EU Package List: 1 x Gas Detector 1 x Instruction Installation Instructions: 1. Alarm installation location: within a radius of 1.5 meters from the air source with good ventilation. (1) LPG has a higher density than air and stays at a low place ar leakage. The alarm should be installed at a place about 0.3 meters away from the ground. (2) the density of gas and carbon monoxide is smaller than that of air. Ar leakage, the alarm should be installed 0.3 meters away from the ceiling. 2. Can not install the alarm position: corner, cabinet and other difficult to circulate the air position;Easy to be smoked directly, such as lampblack position. Application : 1. Power indication: green light, power on, when the alarm goes out. 2. Alarm indicator: red light, flashing when alarm. 3. Turn on the power, the green light or flashing for 3 minutes, the alarm starts to work normally.When the combustible gas leakage is detected to reach the early-warning concentration, the alarm starts to alarm, the green light goes out, the red light flashes, and the continuous alarm sound of "drip-drip-drip" is given out, and the high-frequency wirele alarm signal is given out at the same time.When the concentration of detected gas drops below the early-warning concentration, the alarm stops alarming. 4. Relay control circuit has been reserved on the circuit board in the alarm, which is convenient for users to install. When alarming, the exhaust fan can be controlled by the relay to discharge combustible gas immediately, and the air source electromagnetic valve can also be controlled to close the air source immediately. Regular Testing: 1. Every month with gas into the gas hole, 5 ~ 8 seconds ar the alarm should immediately sound and light alarm, indicating that the alarm works normally. 2. Please always remove dust and grease near the air inlet to prevent air holes from blocking. 3. Pre the test on to simulate alarm and check whether the alarm is in good condition. Handling Methods for Alarm: (1). Please immediately open the door and Window to ensure the flow of air, turn off the harmful air source, do not open or close any electrical switch at this time, in order to avoid the spark ignition gas combustion or explosion. (2). Immediately report to the gas management department, by profeional inspection and proceing. (3). Ar being handled by profeionals, the alarm shall be ventilated.
About payment:
We support the following payment methods. All payments made on are proceed by .
1) We accept , , TT.All major credit cards are accepted through secure payment proceor ESCROW.
2) Payment must be made within of order.
3) If you can't checkout immediately ar auction close, please wait for a few minutes and retry Payments must be completed within .
About shipping:
1. WORLDWIDE SHIPPING.(Except some countries and APO/FPO) 2. Orders proceedtimely ar thepayment verification. 3. We ship to confirmed order addrees. Your order addre MUST MATCH your Shipping addre. 4. The images shown are not the actual item and are for your reference . 5. SERVICE TRANSIT TIME is provided by the carrier and excludes weekends and holidays. Transit times may vary, particularly during the holiday season. 6. If you have not received your shipment within the period, please contact us. We will track the shipment and get back to you as soon as poible with a reply. Our goal is customer satisfaction! 7. Due to stock status and time differences, we will choose to ship your item from our first available warehouse for fast delivery.
8. We seller are not in charge of duty, buyer is responsible for that. Any dispute caused by this is unreasonable.
9. BR buyer please provide the cpf or cnpj, it will be better for you to get it more quickly. thanks
Return and :
1. You have 7 days to contact us and 30 days to return it from the date it was received. If this item is in your poeion more than 7 days, it is considered used and WE WILL NOT ISSUE YOU A OR REPLACEMENT. There are NO EXCEPTIONS! 2. All returned it MUST BE in the packaging and you MUST PROVIDE us with the shipping tracking number, specific reason for the return, and your po#. 3. We will YOUR FULL WINNING BID AMOUNT, upon receipt of the item in its condition and packaging with all components and acceories included, AR BOTH Buyer and Seller cancel the transaction from expre. OR, you may choose to have a replacement.
About feedback:
We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very ant We request that you contact us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily addre your concerns. It is impoible to addre iues if we do not know about them!
About shippingShipping and Packaging All it will be double checked and well packed before sending.It will be dispatched within 2 business days ar buyers pay for the order. It usually takes about 14 to 18 working days for delivering the package to the destination(for remote areas,it may take a little longer).
Special Announcement:Please fill in the correct and detailed consignee, address and phone number in the order. For fast and correct delivery.If you do not receive order within 30 working days,please feel free to contact Customer Service before leaving Negative and Neutral Feedback, we will do our best to help you resolve the problem.TaxNo, you will only pay what is quoted as total cost at checkout, no more. You are not expected to pay any additional duties ores. If you are asked by Customs or our logistic partner to pay duties, please contact our Customer Service .
Your 100% satisfaction is very ant to usIf the product is not on good condition, You can return this product within 14 working days, please contact customer service center before returning.FeedbackYour satisfaction is our first priorityIf you receive the order and it is in good condition,we would be grateful if you would leave us 5 star Positive Feedback for the transaction.
Key Features
Certification:NONE
Origin:CN(Origin)
Model Number:Gas Leakage Detector
What's In the Box
1X Naturaas Alarm r Practical Home Security Lpg Leakage Detector 110-240V Combustible Gas Detector